Evaluasi Tingkat Kualitas Pencahayaan Pada Gedung Fakultas Keguruan Dan Ilmu Pendidikan Universitas Muhammadiyah Purwokerto
DOI:
https://doi.org/10.30595/jrre.v4i2.12790Abstract
Good lighting intensity can affect the quality of performance in activity, improper lighting can also cause mental stress on room users, eye disorders, and disorders of the body. This research was created to analyze the needs and suitability of light quality by performing calculations of lamp types, luxmeter measurements and visualization using Dialux. Dialux is software for simulating, visualizing, and analyzing the performance of lighting systems in geographic locations and environments of specific objects, with optimal lighting situation results. When researching the intensity of lighting in the room in the Building of the Faculty of Teacher Training and Education, one of them in the development laboratory room obtained the results of calculations of 86.66 lux, measurement of luxmeter 83.44 lux, and the results of 109 lux dialux analysis, this is due to shrinkage in the installed lamp, as well as the lack of armature, and lamp point so that the intensity of lighting has not met the Indonesian National Standard of laboratory space of 500 lux. So the solution was made a design recommendation that refers to the Indonesian National Standard. One of the design recommendations made in the development laboratory room obtained results of 561 lux using a type of Meval LED Tube lamp 22 Watts. Because the index in each room is different, when determining the light point must be rounded according to the needs of the room.
Â
Keywords :
Dialux Visualization, Evaluation of lighting levels, Design recommendations, Indonesian National Standard
References
[1] O. R. Aulia, “Evaluasi Penerangan Ruang Kelas Pada Gedung K . H . a . Wahid Hasyim Menggunakan Aplikasi,” Dsp. Repos. Univ. Islam Indones., 2018.
[2] R. N. Putri and M. Trifiananto, “Analisis tingkat pencahayaan di akademi komunitas semen indonesia-gresik,” Tecnoscienza, vol. 2, no. 2, pp. 67–82, 2018.
[3] R. S. Saraswati, B. A. Wibawa, and B. E. Saputra, “Optimization of Natural and Artificial Lighting System in UPGRIS Lecturer’s Workspace using Dialux Evo,” IOP Conf. Ser. Earth Environ. Sci., vol. 738, no. 1, 2021, doi: 10.1088/1755-1315/738/1/012033.
[4] M. L. Nurrohman, P. Feros, Wahyuning, R. F. Madina, and N. Pratiwi, “Efficient Lighting Design for Multiuse Architecture Studio Classroom using Dialux Evo 9,” IOP Conf. Ser. Earth Environ. Sci., vol. 738, no. 1, 2021, doi: 10.1088/1755-1315/738/1/012034.
[5] B. S. N. Standar Nasional Indonesia, “SNI 03-6575-2001 tentang Tata Cara Perancangan Sistem Pencahayaan Buatan pada Bangunan Gedung,” SNI 03-6575-2001 tentang Tata Cara Peranc. Sist. Pencahayaan Buatan pada Bangunan Gedung, pp. 1–32, 2001.
Downloads
Additional Files
Published
How to Cite
Issue
Section
License
Authors who publish with this journal agree to the following terms:
Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).
Jurnal Riset Rekayasa Elektro is licensed under a Creative Commons Attribution 4.0 International License.